Antifreeze for Wet Fire Sprinkler Systems

FSS ProTect GL and FSS ProTect PG are non-toxic antifreezes designed specifically for wet fire protection systems. These bio-stable products are used in place of water and other water-like fluids in sprinkler systems where freezing may either cause damage or interfere with the functioning of systems or equipment. All raw materials are GRAS approved (generally regarded as safe) for accidental animal ingestion, yet resist the growth of bio-mass through its bacteria-static composition.

 

 

FSS ProTect GL

FFS ProTect GL is a Glycerin based material which is compatible with all approved types of pipe, including CPVC sprinkler pipe and fittings.

FSS ProTect PG

FSS ProTect PG is a Propylene Glycol based material which is compatible with all approved types of sprinkler systems, with the exception of CPVC.

 

Properties

FSS ProTect GL

FSS ProTect PG

Color: Orange Red
Density @ 77°F: 1.13 1.02
Viscosity @ 77°F: 7.05 (Centipoise) 6.15 (Centipoise)
pH: 7.0 8.2 - 9.4
Boiling Point: 212°F 222°F
Minimum Flow Temperature: -15°F -15°F
Flash Point: 350°F 214°F
Fire Point: 400°F 220°F
Inhibited Against Corrosion Yes Yes
Bio-Stable Yes Yes

 

Potential Flammability FSS ProTect GL and FSS ProTect PG are not flammable since they have no measurable flash point. Both products could flash or burn if the water content is evaporated off. Note: No harmful fumes are produced.
Health Information FSS ProTect GL and FSS ProTect PG are virtually harmless to animals and plants. Disposal of these materials in conformance with all health codes.
Packaging >2,000-gallon bulk, 330, 275, 55, 30, 15, 5, and 4x1-gallon containers.
Testing Lab grade hydrometer and/or analog refractometer. Test quarterly.
System Requirements All fire protection sprinkler systems that use these products should conform to local, state and NFPA requirements. The use of antifreeze within these systems should also conform to NFPA requirements. Use of antifreeze solutions should also be in conformance with any state or local health codes.

 

Please call for details and pricing.


Visit us at these upcoming Tradeshows:


 

NFPA 2011 conference

 

NFPA 2013
McCormick Place Convention Center
Chicago, Illinois
June 10-12, 2013
Come Visit Us at Booth 247


 

BOMA

BOMA 2013
San Diego Convention Center
San Diego, CA
June 23-25, 2013
Come Visit Us at Booth 307

 



EDUCATIONAL VIDEOS

Video Presentation

View an internal video inspection!




SPRINKLER SYSTEM TREATMENTS FOR:


MIC Corrosion

Oxygen Cell Corrosion

Dezincification Corrosion

Galvanic Corrosion

Graphitic Corrosion